Sound Reduction Systems Technical advice 01204 380074

Section A–A · timber floor · not to scale

Sound Reduction Systems Ltd Bolton · UK

Soundproofing is a build-up.

Mass, decoupling, absorption — assembled in the right order. SRS manufacture the layers for floors, walls and ceilings, and advise on the stack: domestic rooms, party walls, commercial fit-outs and the details in between.

  • 40+ yearsin the acoustic supply industry
  • UK sourced& manufactured
  • IOAsponsor member · accredited technical staff

01 — The build-up

Six layers.
Three mechanisms.
One order.

A floor does not stop sound because one product is clever. It stops sound because a stack of materials does three different jobs — and because the edges, joints and service penetrations are sealed. Change the order and the stack stops working.

Section through a timber floor build-up Six layers, top to bottom: floor finish, acoustic deck, acoustic membrane, resilient bar, structural deck and joist void, with a ceiling below. Each layer is labelled with its role: mass, absorb, seal, decouple, mass, air spring. Floor finish mass Acoustic deck mass + absorb Membrane seal Resilient bar decouple Structural deck mass Joist zone air spring Ceiling mass
Fig. 01 — a typical timber separating floor, drawn as a section Order matters more than any single layer

What each mechanism does

01

Mass

Weight resists being set in motion. Heavy boards and decks take more energy out of the pressure wave before it reaches the room.

finish · deck · ceiling

02

Decoupling

Break the path. A resilient bar separates the ceiling from the joists, so vibration has to cross a flexible connection instead of a rigid one.

resilient bar

03

Absorption

Turn movement into heat. Mineral wool and foam in the void soak up the air movement that would otherwise carry energy through the cavity.

acoustic deck · void

Mechanism, not a rating. The ticks mark where a mechanism acts in the stack — they are not scores, and no acoustic figures are quoted on this page. SRS publish system data in their own datasheets and on their Part E pages.

02 — The parts

Five products,
one position each.

Every SRS product is a layer with a job. The diagram shows where it sits; the photograph shows what arrives on site. Nothing here is a box on a shelf.

SRS / 01

Acoustilay

Acoustic flooring underlay system

A flooring underlay built to sit over an existing deck, adding mass and a little give without lifting the finished floor level more than the detail allows.

Product page
Acoustilay laid over resilient bars on a timber floor
Acoustilay over resilient bars

SRS / 02

Maxideck

Acoustic flooring

A deck system for new and refurbished floors, where the acoustic layer is part of the floor structure rather than something laid on top of it.

Product page
Maxideck acoustic flooring meeting a plastered wall
Maxideck at a wall junction

SRS / 03

Subprimo

Timber flooring underlay

An underlay for timber floors, sized for the domestic job where the finished floor has to stay where it is and the ceiling below stays untouched.

Product page
A completed party floor build-up between two rooms
Party floor, finished

SRS / 04

Impactafoam

Acoustic foam

Foam for joisted floors: it fills the void, takes the sharpness out of impact and leaves the services runs alone.

Product page
Impactafoam fitted between the joists of a timber floor
Impactafoam between joists

SRS / 05

Acoustilay Tilemat

Acoustic underlay for floor tiles

The same idea under a tiled finish — a decoupling mat that keeps the tile bed intact while it works on impact.

Product page
Acoustilay Tilemat laid on a concrete floor
Tilemat on a concrete base

Also in the floor range: Maxipanel 28, Isolayte OS and Isolayte US.

04 — Where it goes

Three surfaces,
one discipline.

The noise tells you which surface to work on. Impact noise travels through the structure; airborne noise travels through the air and the gaps around it.

A · Floors

Section · timber joist floor

Floors

Timber joists, concrete, screed, tiles. The floor build-up carries impact as well as airborne sound, so mass and decoupling usually arrive together.

Soundproofing for floors

B · Walls

Plan · independent lining

Walls

Masonry, independent linings, timber stud partitions. The weak point is rarely the field of the wall — it is the junction with floor, ceiling and services.

Soundproofing for walls

C · Ceilings

Section · suspended ceiling

Ceilings

Maxi 60, dropped, MF and beam-and-block. Often the only accessible side of a separating floor, which makes the ceiling detail the whole job.

Soundproofing for ceilings

05 — Built and measured

Case studies,
not claims.

Cafés, village halls, community centres and a valley in the Lake District. The published case studies show the problem, the assembly and what the people using the room said afterwards.

More installations, in their own words.

All case studies

06 — Documents & tools

Everything a
specifier needs.

Part E solutions, installation animations and the specification generator. If you are writing the detail, start here rather than with the marketing page.

Installation animations

Short sequences showing the order the layers go in — useful on site.

Tools

For architects and specifiers writing the performance requirement.

Datasheets

Product and system datasheets, installation guidance and declarations are published against each product, not in a single bundle. Start with the system you are building:

07 — Advice

Tell us the construction.
We’ll tell you the stack.

SRS manufacture high performance sound insulation and sound absorption products, and advise on any noise problem through a team of Institute of Acoustics accredited technical staff. The advice is the product.

  1. 01

    The construction. Timber joists or concrete, what is above and below, and what you can take up or down.

  2. 02

    The noise. Footsteps and impact, or voices and airborne sound — and where you hear it from.

  3. 03

    The constraint. Floor level, ceiling height, a finished floor you cannot lift, a service you cannot move.